Avatar HL7 2023 Monthly Release 2023.01.00 Acceptance Tests


Update 2 Summary | Details
Admission and Update Client Data forms additional patient information will be included in outbound HL7 messages.
Note - These testing guidelines assume the user is skilled in the use of, at a minimum, the following:
  • Admission
  • HL7 Connection Monitor - HL7 Outbound Transaction Log - View HL7 Message
  • Update Client Data
Scenario 1: Validate 'OBX' data for Outbound 'ADT' HL7 messages contains "Personal Pronouns", "Gender Identity" and "Sexual Orientation" values
Specific Setup:
  • Customization pack HL7 2023 Update 002 is required to test outbound HL7 to RxConnect.
  • An 'ADT-RXCONNECT' and ADT-DIETARY' connection must be configured.
Steps
  1. Go to 'Admission' form for desired patient and set 'Personal Pronouns' to "she/her/her/hers/herself" and click [Submit].
  2. Open 'HL7 Connection Monitor' form, select "desired feed setup to accept 'OBX' segments", click [Show Transaction Log].
  3. On the 'HL7 Outbound Transaction Log' report, validate "the ADT message contains the desired patient name and the 'Personal Pronouns Reported' as "she/her/her/hers/herself".
  4. Go to 'Update Client Data' form for desired patient and select "desired value" from the 'Gender Identity' dropdown and select "desired value" from the 'Sexual Orientation' dropdown and click [Submit].
  5. Open 'HL7 Connection Monitor' form, select "desired feed setup to accept 'OBX' segments", click [Show Transaction Log].
  6. On the 'HL7 Outbound Transaction Log' report, validate "the ADT message contains the desired patient name and the 'Gender Identity' as "value selected in previous step" and the 'Sexual Orientation' as "value selected in previous step".
Topics
• HL7