Skip to main content

Avatar Cal-PM 2024 Update 18

Product Requirements and Recommendations

Avatar Cal-PM required
RADplus required

Product Update Description

An issue is resolved where the 'Current Unit Census' and 'Official Census Report' reports may not respect the 'Time Zone Offset' registry setting value.

Required Updates

None

Included Updates

None

Details

NEW0 CHANGED0 FIXED1
Fixed (1)
Registry Settings - Utilize Local Workstation Time Zone
Resolves an issue to ensure that the 'Current Unit Census' and 'Official Census Report' displays the time stamp based on the time change expected due to the 'Time Zone Offset' registry setting. KB0075935 v0.01
Topics
• Official Census Report • Verify Unit Census
 
Acceptance Tests

AV-95120 Summary | Details
Registry Settings - Utilize Local Workstation Time Zone
Note - These testing guidelines assume the user is skilled in the use of, at a minimum, the following:
  • Current Unit Census
  • Registry Settings (PM)
  • App Dashboard
  • Official Census Report
  • Performing Provider Association - Error
Scenario 1: Utilize Local Workstation Time Zone - Validating timestamp on the 'Current Unit Census' report
Steps
  1. Open the 'Registry Setting' form.
  2. Set the 'Utilize Local Workstation Time Zone' registry setting to 'N'.
  3. Set the 'Time Zone Offset' registry setting to desired positive number.(Please note: The value of the registry setting can be between -12 to +14).
  4. Open the 'Current Unit Census' form.
  5. Select 'Individual' in the 'For Individual Unit Or All' field to generate the report for desired unit in the facility.
  6. Select desired unit.
  7. Click [Process].
  8. Verify the report displays the time stamp based on the time change expected due to the 'Time Zone Offset' registry setting.
  9. Verify the report displays RUN TIME that is current server time + Offset value entered in the registry setting. Please note: The 'RUN DATE' will be updated if the RUN TIME is changed to next or previous date to reflect the time zone offset value.
  10. Close the report.
  11. Close the form.
  12. Open the 'Registry Setting' form.
  13. Set the 'Time Zone Offset' registry setting to 0. (Please note: The value of the registry setting can be between -12 to +14).
  14. Open the 'Current Unit Census' form.
  15. Select 'All' in the 'For Individual Unit Or All' field to generate the report for desired unit in the facility.
  16. Click [Process].
  17. Verify the report displays RUN TIME that is current server time because the offset value entered in the registry setting is 0.
  18. Close the report.
  19. Close the form.
  20. Open the 'Registry Setting' form.
  21. Set the 'Time Zone Offset' registry setting to desired negative value. (Please note: The value of the registry setting can be between -12 to +14).
  22. Open the 'Current Unit Census' form.
  23. Select 'All' in the 'For Individual Unit Or All' field to generate the report for desired unit in the facility.
  24. Click [Process].
  25. Verify the report displays RUN TIME that is current server time + Offset value entered in the registry setting. Please note: RUN DATE will be updated if the RUN TIME changed to next or previous date to reflect the time zone offset value.
  26. Close the report.
  27. Close the form.
  28. Open the 'Registry Setting' form.
  29. Set the 'Utilize Local Workstation Time Zone' registry setting to 'Y'.
  30. Open the 'Current Unit Census' form.
  31. Select desired value in the 'For Individual Unit Or All' field to generate the report for desired unit in the facility.
  32. Select desired unit.
  33. Click [Process].
  34. Verify the report displays current workstation date and time as a RUN DATE and RUN TIME.
  35. Close the report.
  36. Close the form.
Scenario 2: Registry Setting - Time Zone Offset - Validating timestamp on the 'Official Census Report'
Steps
  1. Open the 'Registry Setting' form.
  2. Set the 'Utilize Local Workstation Time Zone' registry setting to 'N'.
  3. Set the 'Time Zone Offset' registry setting to desired positive number.(Please note: The value of the registry setting can be between -12 to +14).
  4. Close the form.
  5. Open the 'Official Census Report' form.
  6. Enter the desired date in the 'Date' field.
  7. Select the desired value in the 'Treatment Setting' field.
  8. Click [Process].
  9. Verify the report displays the time stamp based on the time change expected due to the 'Time Zone Offset' registry setting.
  10. Verify the report displays RUN TIME that is current server time + time zone Offset value entered in the registry setting. Please note: The 'RUN DATE' will be updated if the RUN TIME is changed to next or previous date to reflect the time zone offset value.
  11. Close the form.
  12. Close the form.
  13. Open the 'Registry Setting' form.
  14. Set the 'Time Zone Offset' registry setting to 0. (Please note: The value of the registry setting can be between -12 to +14).
  15. Close the form.
  16. Open the 'Official Census Report' form.
  17. Enter the desired date in the 'Date' field.
  18. Select the desired value in the 'Treatment Setting' field.
  19. Click [Process].
  20. Verify the report displays the time stamp based on the time change expected due to the 'Time Zone Offset' registry setting.
  21. Verify the report displays RUN TIME that is current server time + Offset value entered in the registry setting. Please note: The 'RUN DATE' will be updated if the RUN TIME is changed to next or previous date to reflect the time zone offset value.
  22. Close the form.
  23. Close the form.
  24. Open the 'Registry Setting' form.
  25. Set the 'Time Zone Offset' registry setting to desired negative value. (Please note: The value of the registry setting can be between -12 to +14).
  26. Open the 'Official Census Report' form.
  27. Enter the desired date in the 'Date' field.
  28. Select the desired value in the 'Treatment Setting' field.
  29. Click [Process].
  30. Verify the report displays the time stamp based on the time change expected due to the 'Time Zone Offset' registry setting.
  31. Verify the report displays RUN TIME that is current server time + Offset value entered in the registry setting. Please note: The 'RUN DATE' will be updated if the RUN TIME is changed to next or previous date to reflect the time zone offset value.
  32. Close the form.
  33. Close the form.
  34. Set the 'Utilize Local Workstation Time Zone' registry setting to 'Y'.
  35. Open the 'Current Unit Census' form.
  36. Select desired value in the 'For Individual Unit Or All' field to generate the report for desired unit in the facility.
  37. Select desired unit.
  38. Click [Process].
  39. Verify the report displays current workstation date and time as a RUN DATE and RUN TIME.
  40. Close the report.
  41. Close the form.
Topics
• Official Census Report • Verify Unit Census