Skip to main content

Avatar HL7 2022 Monthly Release 2022.00.00 Acceptance Tests


Update 1 Summary | Details
Avatar HL7 2022 is Installed
Scenario 1: Validate Upgrading Avatar HL7 2021 to 2022 is successful when 2021.03.01 is loaded
Specific Setup:
  • Latest Monthly Release is installed.
Steps
  1. Open the "Product Updates" form.
  2. Select the appropriate [Namespace] from the Application dropdown list
  3. Click [Select Update/Customization Pack].
  4. Browse to the location for the updates and select the Update 1.
  5. Click [OK] on the "File Upload Complete" window.
  6. Click [Review Update/Customization Pack Contents].
  7. Verify Update 1 is included.
  8. Click [Install Update/Customization Pack].
  9. Click [OK] when the install completes.
  10. Click [Close Form].

Topics
• Upgrade
2021 Update 6 Summary | Details
Outbound ADT messaging for Bed Switch/Swap
Note - These testing guidelines assume the user is skilled in the use of, at a minimum, the following:
  • HL7 Connection Monitor
  • Bed Switch
  • Bed Management
Scenario 1: Outbound ADT HL7 message for A17 bed swap/switch
Specific Setup:
  • Two outbound ADT connections must be configured: One with a 'Standard' vendor profile and one with 'RxConnect' environment.
  • Two clients in inpatient episodes must exist. (Client A and Client B)
Steps
  1. Access the 'Bed Switch' form.
  2. Switch the bed assignment for "Client A" and "Client B" for the current date.
  3. Access the ‘HL7 Connection Monitor’ form.
  4. Select the "Outbound ADT- GENERIC" configuration in the 'Select Row' field.
  5. Click [Show Transaction Log].
  6. Validate the ‘HL7 Outbound Transaction Log Report’ is displayed.
  7. Validate that an 'ADT^17' message is displayed for “Client A”.
  8. Click [View HL7 Message].
  9. Validate there are two PV1 segments.
  10. Validate the first PV1-3 is equal to current location of “Client A”.
  11. Validate the first PV1-6 is equal to prior location of “Client A”.
  12. Validate the second PV1-3 is equal to current location of “Client B”.
  13. Validate the second PV1-6 is equal to prior location of “Client B".
  14. Close the report.
  15. Select the "Outbound ADT- RXCONNECT" configuration in the 'Select Row' field.
  16. Click [Show Transaction Log].
  17. Validate the ‘HL7 Outbound Transaction Log Report’ is displayed.
  18. Validate that an 'ADT^17' message is displayed for “Client A”.
  19. Click [View HL7 Message].
  20. Validate there are two PV1 segments.
  21. Validate the first PV1-3 is equal to current location of “Client A”.
  22. Validate the first PV1-6 is equal to prior location of “Client A”.
  23. Validate the second PV1-3 is equal to current location of “Client B".
  24. Validate the second PV1-6 is equal to prior location of “Client B".
  25. Close the report and the form.
  26. Access the 'Bed Management' form.
  27. Switch "Client A's" bed assignment from the current location to an empty available bed.
  28. Access the ‘HL7 Connection Monitor’ form.
  29. Select the "Outbound ADT- GENERIC" configuration in the 'Select Row' field.
  30. Click [Show Transaction Log].
  31. Validate the ‘HL7 Outbound Transaction Log Report’ is displayed.
  32. Validate that an 'ADT^02' message is displayed for “Client A”.
  33. Click [View HL7 Message].
  34. Validate there is one PV1 segments.
  35. Validate the first PV1-3 is equal to current location of “Client A”.
  36. Validate the first PV1-6 is equal to prior location of “Client A”.
  37. Close the report.
  38. Select the "Outbound ADT- RXCONNECT" configuration in the 'Select Row' field.
  39. Click [Show Transaction Log].
  40. Validate the ‘HL7 Outbound Transaction Log Report’ is displayed.
  41. Validate that an 'ADT^02' message is displayed for “Client A”.
  42. Click [View HL7 Message].
  43. Validate there is one PV1 segments.
  44. Validate the first PV1-3 is equal to current location of “Client A”.
  45. Validate the first PV1-6 is equal to prior location of “Client A”.
  46. Close the report.
Topics
• HL7