Avatar CWS 2023 Update 13

Product Requirements and Recommendations

Avatar CWS required
RADplus required

Recommended Update Level

Avatar CWS 2023 Monthly Release 2023.04.00
RADplus 2023 Monthly Release 2023.04.00

Product Update Description

The 'POC Results Entry Configuration' form is changed to no longer require 'Observation Value Unit' if a vital sign is selected in the 'Observation Definition' tab.

Required Updates

None

Included Updates

None

Details

NEW0 CHANGED0 FIXED1
Fixed (1)
POC Results Entry - Observation Value Unit
The 'POC Results Entry Configuration' form is changed to no longer require 'Observation Value Unit' if a vital sign is selected in the 'Observation Definition' tab.
Topics
• POC Results Entry • POC Results Entry Configuration form
 
Acceptance Tests

AV-82706 Summary | Details
POC Results Entry - Observation Value Unit
Note - These testing guidelines assume the user is skilled in the use of, at a minimum, the following:
  • nx-error-dialog
  • POC Results Entry Configuration
Scenario 1: POC Results Entry Configuration form - Observation Value Unit field is not required as vital sign is selected in the 'Observation Definition' tab
Specific Setup:
  • A Prompt Definition (Prompt Definition 1) must be set up via the Avatar CWS 'Site Specific Section Modeling' form for "Vitals Entry - (CWS14000)" such that:
  • 'Site Specific Field' = "SS Vital Signs Integer" or "SS Vital Signs Free Text".
  • 'Exclude from Data Collection Instrument' = "No".
  • 'Initially enabled' = "Yes".
  • The logged in user must have access to the 'POC Results Entry Configuration' form.
Steps
  1. Open the 'POC Results Entry Configuration' form.
  2. Select "Observation Definition" from the 'Section' menu.
  3. Select "Add" from the 'Add/Edit/Delete Observation' field.
  4. Populate the 'Observation ID Code' field.
  5. Select "Prompt Definition 1" from the 'Save as Vital Sign' field.
  6. Validate the 'Observation Value Unit' field contains "Prompt Definition 1 - Units".
  7. Delete the existing value from 'Observation Value Unit' field.
  8. Populate the 'Observation Value Unit' field with any value other than "Prompt Definition 1 - Units" and Press the Tab key.
  9. Validate an "Error Message" is displayed stating "If 'Save as Vital Sign' is defined the Observation Value Unit must either be blank or equal to Value Unit tied to the Vital Sign which is 'SS Vital Signs Free Text 1 - Units'."
  10. Click [OK].
  11. Click [Discard], validate the 'Confirm Close' dialog displays stating "Are you sure you want to Close without saving?" and click [Yes].
Topics
• POC Results Entry • POC Results Entry Configuration form