Skip to main content

Avatar CareFabric 2023 Update 21

Product Requirements / Recommendations

Avatar CareFabric required
Avatar PM required
RADplus required
Avatar Cal-PM

Product Update Form Description

An issue is resolved where filing a 'Specimen Collection' in Avatar eMAR might incorrectly trigger a 'PutHL7LaboratoryOrderHL7Transmission' CareFabric message.

Included Updates

None

Required Updates

None

Details

NEW0 CHANGED0 FIXED1
Fixed (1)
eMAR - Specimen Collection
An issue is resolved to ensure that when collecting a specimen for a lab order,
in Avatar eMAR, a 'PutHL7LaboratoryOrderHL7Transmission' message is not triggered. KB0073554 v0.01
Topics
• NX • Order Entry Console
 
Acceptance Tests

AV-87994 Summary | Details
eMAR - Specimen Collection
Note - These testing guidelines assume the user is skilled in the use of, at a minimum, the following:
  • Orders This Episode
Scenario 1: Task List - Lab - Lab Orders that do not contain an External Lab Vendor
Specific Setup:
  • A lab-type order code must exist that is not associated with an 'External Lab Vendor' or a 'CPT Code'. (Lab Code A)
  • A client must have an active episode. (Client A)
Steps
  1. Select "Client A" and access the Order Entry Console.
  2. Create an order for "Lab Code A".
  3. Access the 'eMAR' widget and complete a specimen collection for the order created using "Lab Code A".
  4. Validate no rows are displayed in the 'SYSTEM.radplus_transfer_queue' and 'SYSTEM.radplus_transfer_err' tables.
Topics
• NX • Order Entry Console